4 min readGuide 8 of 11
Usually, operators check a static bond or ground by eye. They make sure that the ground clamp and the lead are in place. From time to time, they also check the connection with a resistance meter. This guide explains where that check can fail, how static monitoring helps, and how to decide if your operation needs it.
An operator can use the correct wires and tools and still not get a good bond or ground. If the connection does not reach a conductive surface, the static may still not drain.
An object that is not correctly grounded or bonded can collect a static charge. With the right amount of flammable vapour and a spark, an ignition can occur.
This condition may exist with no sign at all to warn the operator.
Newer electronic verification systems remove the guesswork from bonding and grounding. They give a continuous visual confirmation that the bonded or grounded connection is correct.
This guide compares two of these systems: the G2 Series Ground Monitoring Systems and the StaticSure Portable Static Monitoring System. Both show clearly when a ground connection or bond is in place and static electricity drains. The two systems work on a similar idea. But they have different features, and they use different ways to tell the operator if the connection is correct or not.

G2 Series systems are stationary systems that you mount in place. They are large. They need an electrical input. For use inside hazardous locations, they need a heavy explosion-proof enclosure.
A G2 Series system uses an intrinsically safe monitoring circuit that drives a switching relay. The operator connects the self-releasing clamp and cable to a conducting material. This completes the circuit, and a green light shows that a ground connection is in place. If there is no correct ground, a red light stays on.
The G2 Series monitors two paths for low resistance:
An interruption in either path (any resistance above 5 ohms) shuts down the system.
You can interlock the system with filling equipment. Then no flammable product can transfer until the ground is in place. For example, the system can let a pump start only when there is a good static ground. If the circuit breaks because the operator releases the grounding clamp, or because of a different ground interruption, the control relay opens. The system then shows a red light. Filling equipment that the system controls also stops until the ground is in place again.
A G2 Series system will:
Standard options include an aluminum or a bronze clamp, a straight or a self-coiling cable, and different cable storage and retracting reels.
Operators typically use G2 Series systems in bulk train or truck unloading areas.

StaticSure is a battery-operated, lightweight and portable device. It is intrinsically safe, and you can use it in hazardous locations. StaticSure helps you comply with safety regulations and keep a safe work environment.
Use StaticSure with correct bonding and grounding clamps and cables. It then helps make sure that a static bond is in place before you handle flammable materials.
The intrinsically safe electronics in StaticSure monitor the full connection from the clamp to the ground point. If the connection is not good enough to drain static electricity, StaticSure warns the operator with a very bright, flashing red LED. The LED keeps flashing until the operator corrects the problem and static electricity can drain from the equipment again.
The unit is small. You can use it as a portable unit, or mount it to a wall or a vehicle. Its modular design uses standard industrial static grounding clamps. You can quickly disconnect them and connect them again in the configuration that the work needs.
Operators typically use StaticSure in drumming or other portable operations. Many independent carriers of flammable products also keep a StaticSure in the truck. They use it when the bulk unloading area at a customer site does not have a G2 type system.
Do you need a StaticSure configuration that is not on the product page? Contact us and we will make it for you.
| G2 Series Ground Monitoring Systems | StaticSure Portable Static Monitoring System | |
|---|---|---|
| Type | Stationary, mounted system | Portable device that you can also mount to a wall or a vehicle |
| Size | Large | Small and lightweight |
| Power | Electrical input | Battery |
| Hazardous locations | Needs a heavy explosion-proof enclosure inside hazardous locations | Intrinsically safe, for use in hazardous locations |
| What it monitors | The path from the ground unit to the clamp, and a separate cable connection to actual ground | The full connection from the clamp to the ground point |
| Signal | Green light when the ground connection is in place. Red light when it is not. | Very bright red LED that flashes until the operator corrects the problem |
| Typical use | Bulk train or truck unloading areas | Drumming and other portable operations |
Both systems have a role in a correct static grounding process. As a safety manager or facility operator, ask yourself two questions:
Not sure which system suits your site? Contact us.